20
13. Data Storage for System Diagnostics
The following data is stored by the thermostat to allow advanced system diagnostics:
• Average cooling set-point while cooling is active (“SC”)
• Average heating set-point while heating is active (“SH”)
• Average number of cooling cycles per day while in cooling mode (“CC”)
• Average number of heating cycles per day while in heating mode (“CH”)
• Average length of cooling cycle in minutes (“LC”)
• Average length of heating cycle in minutes (“LH”)
These values are cumulative from the time the thermostat is placed into service.
To access these values follow these steps:
1. Press and hold (6 seconds) the On/Off button to set the
system mode to OFF
2. Using the “+” and “-“ buttons set the temperature set-point
to 55°F.
3. When the display stops flashing, press and hold the Select
button.
4. Use the Select button to advance through the steps.