7. Advanced Setup
The ERV-24-HC11 thermostat with FanCycler
®
has enhanced features to compliment
controlled mechanical ventilation systems and combination space and domestic hot water
heating systems.
Follow the steps below to set the unit’s advanced features:
7.1 Enter the Advanced Setup screens of the thermostat
a. Press and hold (4 seconds) the On/Off button to turn
the thermostat OFF.
b. Using the “+” and “-“ buttons, move the temperature
set-point to 50
o
F.
c. Wait until the display stop flashing, then press and hold
(6 seconds) the Select button.
The Select button is used for navigation between options.
The “+” and “-“ buttons are used for setting the current feature.